Enterasys Enterasys SecureStack B2 B2G124-24 Specifications

Browse online or download Specifications for Network switches Enterasys Enterasys SecureStack B2 B2G124-24. Enterasys Enterasys SecureStack B2 B2G124-24 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 488
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SecureStack B2
Stackable Switches
Configuration Guide
Firmware Version 1.01.xx
P/N 9034133-03
Page view 0
1 2 3 4 5 6 ... 487 488

Summary of Contents

Page 1 - SecureStack B2

SecureStack B2Stackable SwitchesConfiguration GuideFirmware Version 1.01.xxP/N 9034133-03

Page 2

Contentsviii SecureStack B2 Configuration Guide3PORT CONFIGURATION3.1 Port Configuration Summary...

Page 3 - 1.01.xx

Startup and General Configuration SummaryConfiguring Power over Ethernet (PoE)2-70 SecureStack B2 Configuration Guide2.1.13.3 set inlinepower trapUse

Page 4 - Firmware License Agreement

Startup and General Configuration SummaryConfiguring Power over Ethernet (PoE)SecureStack B2 Configuration Guide 2-712.1.13.4 show port inlinepowerUse

Page 5

Startup and General Configuration SummaryConfiguring Power over Ethernet (PoE)2-72 SecureStack B2 Configuration Guide2.1.13.5 set port inlinepowerUse

Page 6

Startup and General Configuration SummaryDownloading a New Firmware ImageSecureStack B2 Configuration Guide 2-732.1.14 Downloading a New Firmware Imag

Page 7

Startup and General Configuration SummaryDownloading a New Firmware Image2-74 SecureStack B2 Configuration Guide2.1.14.2 Downloading via the Serial Po

Page 8

Startup and General Configuration SummaryDownloading a New Firmware ImageSecureStack B2 Configuration Guide 2-753. Type 2. The following baud rate sel

Page 9

Startup and General Configuration SummaryDownloading a New Firmware Image2-76 SecureStack B2 Configuration Guide7. From the boot menu options screen,

Page 10 - PORT CONFIGURATION

Startup and General Configuration SummaryDownloading a New Firmware ImageSecureStack B2 Configuration Guide 2-772.1.14.3 show boot systemUse this comm

Page 11 - SNMP CONFIGURATION

Startup and General Configuration SummaryDownloading a New Firmware Image2-78 SecureStack B2 Configuration Guide2.1.14.4 set boot systemUse this comma

Page 12 - SPANNING TREE CONFIGURATION

Startup and General Configuration SummaryStarting and Configuring TelnetSecureStack B2 Configuration Guide 2-792.1.15 Starting and Configuring TelnetP

Page 13 - 802.1Q VLAN CONFIGURATION

ContentsSecureStack B2 Configuration Guide ix3.5.4.3 set lacp asyspri ... 3-413.5.4.4 set lacp

Page 14 - Contents

Startup and General Configuration SummaryStarting and Configuring Telnet2-80 SecureStack B2 Configuration Guide2.1.15.1 show telnetUse this command to

Page 15 - IGMP CONFIGURATION

Startup and General Configuration SummaryStarting and Configuring TelnetSecureStack B2 Configuration Guide 2-812.1.15.2 set telnetUse this command to

Page 16

Startup and General Configuration SummaryManaging Configuration and Image Files2-82 SecureStack B2 Configuration Guide2.1.16 Managing Configuration an

Page 17 - SECURITY CONFIGURATION

Startup and General Configuration SummaryManaging Configuration and Image FilesSecureStack B2 Configuration Guide 2-832.1.16.1 dirUse this command to

Page 18

Startup and General Configuration SummaryManaging Configuration and Image Files2-84 SecureStack B2 Configuration Guide2.1.16.2 show configUse this com

Page 19

Startup and General Configuration SummaryManaging Configuration and Image FilesSecureStack B2 Configuration Guide 2-85B2(rw)->show config!#***** NO

Page 20

Startup and General Configuration SummaryManaging Configuration and Image Files2-86 SecureStack B2 Configuration Guide2.1.16.3 configureUse this comma

Page 21

Startup and General Configuration SummaryManaging Configuration and Image FilesSecureStack B2 Configuration Guide 2-872.1.16.4 copy Use this command t

Page 22

Startup and General Configuration SummaryManaging Configuration and Image Files2-88 SecureStack B2 Configuration Guide2.1.16.5 delete Use this command

Page 23 - About This Guide

Startup and General Configuration SummaryConfiguring CDPSecureStack B2 Configuration Guide 2-892.1.17 Configuring CDPPurposeTo review and configure th

Page 24 - STRUCTURE OF THIS GUIDE

Contentsx SecureStack B2 Configuration Guide4.3.5 Configuring SNMP Target Parameters ... 4-394.3.5.1 show snmp t

Page 25 - RELATED DOCUMENTS

Startup and General Configuration SummaryConfiguring CDP2-90 SecureStack B2 Configuration Guide2.1.17.1 show cdpUse this command to display the status

Page 26 - Related Documents

Startup and General Configuration SummaryConfiguring CDPSecureStack B2 Configuration Guide 2-91Table 2-7 show cdp Output DetailsOutput What It Display

Page 27 - Introduction

Startup and General Configuration SummaryConfiguring CDP2-92 SecureStack B2 Configuration Guide2.1.17.2 set cdp stateUse this command to enable or dis

Page 28 - 1.2 DEVICE MANAGEMENT METHODS

Startup and General Configuration SummaryConfiguring CDPSecureStack B2 Configuration Guide 2-932.1.17.3 set cdp authUse this command to set a global C

Page 29 - 1.3 GETTING HELP

Startup and General Configuration SummaryConfiguring CDP2-94 SecureStack B2 Configuration Guide2.1.17.4 set cdp intervalUse this command to set the me

Page 30 - Getting Help

Startup and General Configuration SummaryConfiguring CDPSecureStack B2 Configuration Guide 2-952.1.17.5 set cdp hold-timeUse this command to set the h

Page 31

Startup and General Configuration SummaryConfiguring CDP2-96 SecureStack B2 Configuration Guide2.1.17.6 clear cdpUse this command to reset CDP discove

Page 32 - Factory Default Settings

Startup and General Configuration SummaryClearing and Closing the CLISecureStack B2 Configuration Guide 2-972.1.18 Clearing and Closing the CLIPurpos

Page 33

Startup and General Configuration SummaryClearing and Closing the CLI2-98 SecureStack B2 Configuration Guide2.1.18.1 cls (clear screen)Use this comman

Page 34

Startup and General Configuration SummaryResetting the DeviceSecureStack B2 Configuration Guide 2-992.1.18.2 exit Use either of these commands to leav

Page 35 - 2.1.3 CLI Command Modes

ContentsSecureStack B2 Configuration Guide xi5.2.1.17 clear spantree priority... 5-235.2.1.18 set spantr

Page 36 - Enabling / disabling WebView:

Startup and General Configuration SummaryResetting the Device2-100 SecureStack B2 Configuration Guide2.1.19.1 resetUse this command to reset the devic

Page 37 - • rw for Read-Write access

Startup and General Configuration SummaryResetting the DeviceSecureStack B2 Configuration Guide 2-1012.1.19.2 clear configUse this command to clear th

Page 38 - User Account

Startup and General Configuration SummaryResetting the Device2-102 SecureStack B2 Configuration Guide

Page 39

SecureStack B2 Configuration Guide 3-13Port ConfigurationThis chapter describes the Port Configuration set of commands and how to use them.3.1 PORT CO

Page 40 - --More-- to indicate

Port Configuration SummaryPort String Syntax Used in the CLI3-2 SecureStack B2 Configuration Guide3.1.1 Port String Syntax Used in the CLICommands req

Page 41 - Key Sequence Command

Process Overview: Port ConfigurationPort String Syntax Used in the CLISecureStack B2 Configuration Guide 3-3This example shows the port-string syntax

Page 42

Port Configuration Command SetReviewing Port Status3-4 SecureStack B2 Configuration Guide3.3 PORT CONFIGURATION COMMAND SET3.3.1 Reviewing Port Status

Page 43

Port Configuration Command SetReviewing Port StatusSecureStack B2 Configuration Guide 3-53.3.1.1 show port Use this command to display whether or not

Page 44 - Important

Port Configuration Command SetReviewing Port Status3-6 SecureStack B2 Configuration Guide3.3.1.2 show port statusUse this command to display operating

Page 45

Port Configuration Command SetReviewing Port StatusSecureStack B2 Configuration Guide 3-7Admin Status Whether the specified port is enabled (up) or di

Page 46

Contentsxii SecureStack B2 Configuration Guide6.3.4 Configuring the VLAN Egress List ... 6-206.3.4.1 show

Page 47 - 2.1.10.2 show switch

Port Configuration Command SetReviewing Port Status3-8 SecureStack B2 Configuration Guide3.3.1.3 show port countersUse this command to display port co

Page 48

Port Configuration Command SetReviewing Port StatusSecureStack B2 Configuration Guide 3-9ExamplesThis example shows how to display all counter statist

Page 49

Port Configuration Command SetReviewing Port Status3-10 SecureStack B2 Configuration GuideTable 3-2 show port counters Output DetailsOutput What It Di

Page 50

Port Configuration Command SetDisabling / Enabling PortsSecureStack B2 Configuration Guide 3-113.3.2 Disabling / Enabling PortsPurposeTo disable and r

Page 51 - 2.1.10.5 set switch

Port Configuration Command SetDisabling / Enabling Ports3-12 SecureStack B2 Configuration Guide3.3.2.1 set port disableUse this command to administrat

Page 52 - 2.1.10.6 set switch copy-sw

Port Configuration Command SetDisabling / Enabling PortsSecureStack B2 Configuration Guide 3-133.3.2.2 set port enableUse this command to administrati

Page 53

Port Configuration Command SetDisabling / Enabling Ports3-14 SecureStack B2 Configuration Guide3.3.2.3 show port trapUse this command to display wheth

Page 54

Port Configuration Command SetSetting Speed and Duplex ModeSecureStack B2 Configuration Guide 3-153.3.3 Setting Speed and Duplex ModePurposeTo review

Page 55 - 2.1.10.9 set switch member

Port Configuration Command SetSetting Speed and Duplex Mode3-16 SecureStack B2 Configuration Guide3.3.3.1 show port speedUse this command to display t

Page 56 - 2.1.10.10 clear switch member

Port Configuration Command SetSetting Speed and Duplex ModeSecureStack B2 Configuration Guide 3-173.3.3.2 set port speedUse this command to set the de

Page 57

ContentsSecureStack B2 Configuration Guide xiii8PORT PRIORITY AND RATE LIMITING CONFIGURATION8.1 Port Priority Configuration Summary...

Page 58

Port Configuration Command SetSetting Speed and Duplex Mode3-18 SecureStack B2 Configuration Guide3.3.3.3 show port duplexUse this command to display

Page 59 - 2.1.10.13 save config

Port Configuration Command SetSetting Speed and Duplex ModeSecureStack B2 Configuration Guide 3-193.3.3.4 set port duplexUse this command to set the d

Page 60

Port Configuration Command SetEnabling / Disabling Jumbo Frame Support3-20 SecureStack B2 Configuration Guide3.3.4 Enabling / Disabling Jumbo Frame Su

Page 61 - 2.1.11.1 show system login

Port Configuration Command SetEnabling / Disabling Jumbo Frame SupportSecureStack B2 Configuration Guide 3-213.3.4.1 show port jumbo Use this command

Page 62

Port Configuration Command SetEnabling / Disabling Jumbo Frame Support3-22 SecureStack B2 Configuration Guide3.3.4.2 set port jumbo Use this command t

Page 63 - 2.1.11.2 set system login

Port Configuration Command SetSetting Auto-NegotiationSecureStack B2 Configuration Guide 3-233.3.4.3 clear port jumbo Use this command to reset jumbo

Page 64 - 2.1.11.3 clear system login

Port Configuration Command SetSetting Auto-Negotiation3-24 SecureStack B2 Configuration Guide3.3.5.1 show port negotiationUse this command to display

Page 65 - 2.1.11.4 set password

Port Configuration Command SetSetting Auto-NegotiationSecureStack B2 Configuration Guide 3-253.3.5.2 set port negotiationUse this command to enable or

Page 66

Port Configuration Command SetSetting Flow Control3-26 SecureStack B2 Configuration Guide3.3.6 Setting Flow ControlPurposeTo review, enable or disable

Page 67

Port Configuration Command SetSetting Flow ControlSecureStack B2 Configuration Guide 3-273.3.6.1 show flowcontrolUse this command to display the flow

Page 68

Contentsxiv SecureStack B2 Configuration Guide10.2.1.4 show logging default ... 10-710.2.1.5 set loggin

Page 69 - 2.1.11.8 show system lockout

Port Configuration Command SetSetting Flow Control3-28 SecureStack B2 Configuration Guide3.3.6.3 set flowcontrolUse this command to enable or disable

Page 70 - 2.1.11.9 set system lockout

Port MirroringMirroring FeaturesSecureStack B2 Configuration Guide 3-293.4 PORT MIRRORINGThe SecureStack device allows you to mirror (or redirect) the

Page 71

Port MirroringSetting Port Mirroring3-30 SecureStack B2 Configuration Guide3.4.2.1 show port mirroringUse this command to display the source and targe

Page 72

Port MirroringSetting Port MirroringSecureStack B2 Configuration Guide 3-313.4.2.2 set port mirroringUse this command to create a new mirroring relati

Page 73 - 2.1.12.1 show ip address

Port MirroringSetting Port Mirroring3-32 SecureStack B2 Configuration Guide3.4.2.3 clear port mirroringUse this command to clear a port mirroring rela

Page 74 - 2.1.12.2 show ip protocol

Link Aggregation Control Protocol (LACP)LACP OperationSecureStack B2 Configuration Guide 3-333.5 LINK AGGREGATION CONTROL PROTOCOL (LACP)Using multipl

Page 75 - 2.1.12.3 set ip address

Link Aggregation Control Protocol (LACP)LACP Terminology3-34 SecureStack B2 Configuration Guide• Uses information from the partner device’s link aggre

Page 76 - 2.1.12.4 show system

Link Aggregation Control Protocol (LACP)SecureStack B2 Usage ConsiderationsSecureStack B2 Configuration Guide 3-353.5.3 SecureStack B2 Usage Considera

Page 77

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-36 SecureStack B2 Configuration Guideof aggregations possible. If the switch is

Page 78 - 2.1.12.5 show system hardware

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-37CommandsThe commands used to review and con

Page 79

ContentsSecureStack B2 Configuration Guide xv11SECURITY CONFIGURATION11.1 Overview of Security Methods ...

Page 80 - 2.1.12.7 show time

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-38 SecureStack B2 Configuration Guide3.5.4.1 set lacpUse this command to disable

Page 81 - 2.1.12.8 set time

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-393.5.4.2 show lacpUse this command to displa

Page 82 - 2.1.12.9 show summertime

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-40 SecureStack B2 Configuration GuideTable 3-4 show lacp Output DetailsOutput Wh

Page 83 - 2.1.12.10 set summertime

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-413.5.4.3 set lacp asyspriUse this command to

Page 84 - 2.1.12.11 set summertime date

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-42 SecureStack B2 Configuration Guide3.5.4.4 set lacp aadminkeyUse this command

Page 85 - 02:00 60

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-433.5.4.5 clear lacpUse this command to clear

Page 86 - 2.1.12.13 clear summertime

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-44 SecureStack B2 Configuration Guide3.5.4.6 set lacp staticUse this command to

Page 87 - 2.1.12.14 set prompt

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-453.5.4.7 clear lacp staticUse this command t

Page 88 - 2.1.12.15 show version

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-46 SecureStack B2 Configuration Guide3.5.4.8 show port lacpUse this command to d

Page 89 - 2.1.12.16 set system name

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-47This example shows how to display summarize

Page 90 - 2.1.12.17 set system location

Contentsxvi SecureStack B2 Configuration Guide

Page 91 - 2.1.12.18 set system contact

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-48 SecureStack B2 Configuration Guide3.5.4.9 set port lacpUse this command to se

Page 92 - 2.1.12.19 set length

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-49aportpri aportpri Sets the port’s actor por

Page 93 - 2.1.12.20 show logout

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-50 SecureStack B2 Configuration GuideCommand Defaults• At least one parameter mu

Page 94 - 2.1.12.21 set logout

Link Aggregation Control Protocol (LACP)Configuring Link AggregationSecureStack B2 Configuration Guide 3-513.5.4.10 clear port lacpUse this command to

Page 95 - 2.1.12.22 show console

Link Aggregation Control Protocol (LACP)Configuring Link Aggregation3-52 SecureStack B2 Configuration GuideCommand DefaultsNone.Command ModeRead-Write

Page 96 - 2.1.12.23 set console baud

Link Aggregation Control Protocol (LACP)Configuring Broadcast SuppressionSecureStack B2 Configuration Guide 3-533.5.5 Configuring Broadcast Suppressio

Page 97

Link Aggregation Control Protocol (LACP)Configuring Broadcast Suppression3-54 SecureStack B2 Configuration Guide3.5.5.1 show broadcastUse this command

Page 98 - 2.1.13.1 show inlinepower

Link Aggregation Control Protocol (LACP)Configuring Broadcast SuppressionSecureStack B2 Configuration Guide 3-553.5.5.2 set broadcastUse this command

Page 99

Link Aggregation Control Protocol (LACP)Configuring Broadcast Suppression3-56 SecureStack B2 Configuration Guide

Page 100 - 2.1.13.3 set inlinepower trap

SecureStack B2 Configuration Guide 4-14SNMP ConfigurationThis chapter describes the Simple Network Management Protocol (SNMP) set of commands and how

Page 101

SecureStack B2 Configuration Guide xviiFiguresFigure Page2-1 Sample CLI Default Description ...

Page 102 - 2.1.13.5 set port inlinepower

SNMP Configuration SummarySNMPv34-2 SecureStack B2 Configuration GuideDoes not apply to MATRIX E7.4.1.2 SNMPv3SNMPv3 is an interoperable standards-bas

Page 103 - • Tera Term Pro Version 2.3

SNMP Configuration SummaryAbout SNMP Security Models and LevelsSecureStack B2 Configuration Guide 4-34.1.3 About SNMP Security Models and LevelsAn SNM

Page 104

SNMP Configuration SummaryUsing SNMP Contexts to Access Specific MIBs4-4 SecureStack B2 Configuration Guide4.1.4 Using SNMP Contexts to Access Specifi

Page 105

Process Overview: SNMP ConfigurationUsing SNMP Contexts to Access Specific MIBsSecureStack B2 Configuration Guide 4-54.2 PROCESS OVERVIEW: SNMP CONFIG

Page 106

SNMP Configuration Command SetReviewing SNMP Statistics4-6 SecureStack B2 Configuration Guide4.3 SNMP CONFIGURATION COMMAND SET4.3.1 Reviewing SNMP St

Page 107 - 2.1.14.3 show boot system

SNMP Configuration Command SetReviewing SNMP StatisticsSecureStack B2 Configuration Guide 4-74.3.1.1 show snmp engineidUse this command to display the

Page 108 - 2.1.14.4 set boot system

SNMP Configuration Command SetReviewing SNMP Statistics4-8 SecureStack B2 Configuration Guide4.3.1.2 show snmp countersUse this command to display SNM

Page 109 - Commands

SNMP Configuration Command SetReviewing SNMP StatisticsSecureStack B2 Configuration Guide 4-9ExampleThis example shows how to display SNMP counter val

Page 110 - 2.1.15.1 show telnet

SNMP Configuration Command SetReviewing SNMP Statistics4-10 SecureStack B2 Configuration GuideTable 4-3 show snmp counters Output DetailsOutput What I

Page 111 - 2.1.15.2 set telnet

SNMP Configuration Command SetReviewing SNMP StatisticsSecureStack B2 Configuration Guide 4-11snmpInTotalReqVars Number of MIB objects retrieved succe

Page 113 - 2.1.16.1 dir

Figuresxviii SecureStack B2 Configuration Guide

Page 114 - 2.1.16.2 show config

SNMP Configuration Command SetReviewing SNMP Statistics4-12 SecureStack B2 Configuration GuidesnmpOutGetNexts Number of SNMP Get-Next PDUs generated b

Page 115

SNMP Configuration Command SetReviewing SNMP StatisticsSecureStack B2 Configuration Guide 4-13usmStatsWrongDigests Number of packets received by the S

Page 116 - 2.1.16.3 configure

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and Communities4-14 SecureStack B2 Configuration Guide4.3.2 Configuring SNMP Users, Grou

Page 117 - 2.1.16.4 copy

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and CommunitiesSecureStack B2 Configuration Guide 4-154.3.2.1 show snmp userUse this com

Page 118 - 2.1.16.5 delete

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and Communities4-16 SecureStack B2 Configuration GuideThis example shows how to display

Page 119 - 2.1.17 Configuring CDP

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and CommunitiesSecureStack B2 Configuration Guide 4-174.3.2.2 set snmp userUse this comm

Page 120 - 2.1.17.1 show cdp

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and Communities4-18 SecureStack B2 Configuration Guide4.3.2.3 clear snmp userUse this co

Page 121 - Output What It Displays

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and CommunitiesSecureStack B2 Configuration Guide 4-194.3.2.4 show snmp groupUse this co

Page 122 - 2.1.17.2 set cdp state

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and Communities4-20 SecureStack B2 Configuration GuideExampleThis example shows how to d

Page 123 - 2.1.17.3 set cdp auth

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and CommunitiesSecureStack B2 Configuration Guide 4-214.3.2.5 set snmp groupUse this com

Page 124 - 2.1.17.4 set cdp interval

SecureStack B2 Configuration Guide xixTablesTabl e Page2-1 Default Device Settings ...

Page 125 - 2.1.17.5 set cdp hold-time

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and Communities4-22 SecureStack B2 Configuration Guide4.3.2.6 clear snmp groupUse this c

Page 126 - 2.1.17.6 clear cdp

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and CommunitiesSecureStack B2 Configuration Guide 4-234.3.2.7 show snmp communityUse thi

Page 127

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and Communities4-24 SecureStack B2 Configuration Guide4.3.2.8 set snmp communityUse this

Page 128 - 2.1.18.1 cls (clear screen)

SNMP Configuration Command SetConfiguring SNMP Users, Groups, and CommunitiesSecureStack B2 Configuration Guide 4-254.3.2.9 clear snmp communityUse th

Page 129 - 2.1.19 Resetting the Device

SNMP Configuration Command SetConfiguring SNMP Access Rights4-26 SecureStack B2 Configuration Guide4.3.3 Configuring SNMP Access RightsPurposeTo revie

Page 130 - 2.1.19.1 reset

SNMP Configuration Command SetConfiguring SNMP Access RightsSecureStack B2 Configuration Guide 4-274.3.3.1 show snmp accessUse this command to display

Page 131 - 2.1.19.2 clear config

SNMP Configuration Command SetConfiguring SNMP Access Rights4-28 SecureStack B2 Configuration GuideExampleThis example shows how to display SNMP acces

Page 132 - Resetting the Device

SNMP Configuration Command SetConfiguring SNMP Access RightsSecureStack B2 Configuration Guide 4-29Write View Name of the view that allows this group

Page 133 - Port Configuration

SNMP Configuration Command SetConfiguring SNMP Access Rights4-30 SecureStack B2 Configuration Guide4.3.3.2 set snmp accessUse this command to set an S

Page 134 - Examples

SNMP Configuration Command SetConfiguring SNMP Access RightsSecureStack B2 Configuration Guide 4-31• If write view is not specified, none will be appl

Page 135

Tablesxx SecureStack B2 Configuration Guide

Page 136 - 3.3.1 Reviewing Port Status

SNMP Configuration Command SetConfiguring SNMP Access Rights4-32 SecureStack B2 Configuration Guide4.3.3.3 clear snmp accessUse this command to clear

Page 137 - 3.3.1.1 show port

SNMP Configuration Command SetConfiguring SNMP MIB ViewsSecureStack B2 Configuration Guide 4-334.3.4 Configuring SNMP MIB ViewsPurposeTo review and co

Page 138 - 3.3.1.2 show port status

SNMP Configuration Command SetConfiguring SNMP MIB Views4-34 SecureStack B2 Configuration Guide4.3.4.1 show snmp viewUse this command to display the M

Page 139

SNMP Configuration Command SetConfiguring SNMP MIB ViewsSecureStack B2 Configuration Guide 4-35ExampleThis example shows how to display SNMP MIB view

Page 140 - 3.3.1.3 show port counters

SNMP Configuration Command SetConfiguring SNMP MIB Views4-36 SecureStack B2 Configuration Guide4.3.4.2 show snmp contextUse this command to display th

Page 141

SNMP Configuration Command SetConfiguring SNMP MIB ViewsSecureStack B2 Configuration Guide 4-374.3.4.3 set snmp viewUse this command to set a MIB conf

Page 142

SNMP Configuration Command SetConfiguring SNMP MIB Views4-38 SecureStack B2 Configuration Guide4.3.4.4 clear snmp viewUse this command to delete an SN

Page 143

SNMP Configuration Command SetConfiguring SNMP Target ParametersSecureStack B2 Configuration Guide 4-394.3.5 Configuring SNMP Target ParametersPurpose

Page 144 - 3.3.2.1 set port disable

SNMP Configuration Command SetConfiguring SNMP Target Parameters4-40 SecureStack B2 Configuration Guide4.3.5.1 show snmp targetparamsUse this command

Page 145 - 3.3.2.2 set port enable

SNMP Configuration Command SetConfiguring SNMP Target ParametersSecureStack B2 Configuration Guide 4-41ExampleThis example shows how to display SNMP t

Page 146 - 3.3.2.3 show port trap

SecureStack B2 Configuration Guide xxiAbout This GuideWelcome to the Enterasys Networks SecureStack B2 Configuration Guide. This manual explains how t

Page 147

SNMP Configuration Command SetConfiguring SNMP Target Parameters4-42 SecureStack B2 Configuration GuideStorage type Whether entry is stored in volatil

Page 148 - 3.3.3.1 show port speed

SNMP Configuration Command SetConfiguring SNMP Target ParametersSecureStack B2 Configuration Guide 4-434.3.5.2 set snmp targetparamsUse this command t

Page 149 - 3.3.3.2 set port speed

SNMP Configuration Command SetConfiguring SNMP Target Parameters4-44 SecureStack B2 Configuration GuideExampleThis example shows how to set SNMP targe

Page 150 - 3.3.3.3 show port duplex

SNMP Configuration Command SetConfiguring SNMP Target ParametersSecureStack B2 Configuration Guide 4-454.3.5.3 clear snmp targetparamsUse this command

Page 151 - 3.3.3.4 set port duplex

SNMP Configuration Command SetConfiguring SNMP Target Addresses4-46 SecureStack B2 Configuration Guide4.3.6 Configuring SNMP Target Addresses PurposeT

Page 152

SNMP Configuration Command SetConfiguring SNMP Target AddressesSecureStack B2 Configuration Guide 4-474.3.6.1 show snmp targetaddrUse this command to

Page 153 - 3.3.4.1 show port jumbo

SNMP Configuration Command SetConfiguring SNMP Target Addresses4-48 SecureStack B2 Configuration GuideTable 4-9 show snmp targetaddr Output DetailsOut

Page 154 - 3.3.4.2 set port jumbo

SNMP Configuration Command SetConfiguring SNMP Target AddressesSecureStack B2 Configuration Guide 4-494.3.6.2 set snmp targetaddrUse this command to c

Page 155 - 3.3.4.3 clear port jumbo

SNMP Configuration Command SetConfiguring SNMP Target Addresses4-50 SecureStack B2 Configuration GuideCommand Defaults• If not specified, udpport will

Page 156 - 3.3.5.1 show port negotiation

SNMP Configuration Command SetConfiguring SNMP Target AddressesSecureStack B2 Configuration Guide 4-514.3.6.3 clear snmp targetaddrUse this command to

Page 157 - 3.3.5.2 set port negotiation

Structure of This Guidexxii SecureStack B2 Configuration GuideSTRUCTURE OF THIS GUIDEThe guide is organized as follows: Chapter 1, Introduction, provi

Page 158 - 3.3.6 Setting Flow Control

SNMP Configuration Command SetConfiguring SNMP Notification Parameters4-52 SecureStack B2 Configuration Guide4.3.7 Configuring SNMP Notification Param

Page 159 - 3.3.6.1 show flowcontrol

SNMP Configuration Command SetConfiguring SNMP Notification ParametersSecureStack B2 Configuration Guide 4-534.3.7.1 show snmp notifyUse this command

Page 160 - 3.3.6.3 set flowcontrol

SNMP Configuration Command SetConfiguring SNMP Notification Parameters4-54 SecureStack B2 Configuration GuideTable 4-10 show snmp notify Output Detail

Page 161 - 3.4.2 Setting Port Mirroring

SNMP Configuration Command SetConfiguring SNMP Notification ParametersSecureStack B2 Configuration Guide 4-554.3.7.2 set snmp notifyUse this command t

Page 162 - 3.4.2.1 show port mirroring

SNMP Configuration Command SetConfiguring SNMP Notification Parameters4-56 SecureStack B2 Configuration Guide4.3.7.3 clear snmp notifyUse this command

Page 163 - 3.4.2.2 set port mirroring

SNMP Configuration Command SetConfiguring SNMP Notification ParametersSecureStack B2 Configuration Guide 4-574.3.7.4 show snmp notifyfilterUse this co

Page 164 - 3.4.2.3 clear port mirroring

SNMP Configuration Command SetConfiguring SNMP Notification Parameters4-58 SecureStack B2 Configuration Guide4.3.7.5 set snmp notifyfilterUse this com

Page 165 - 3.5.1 LACP Operation

SNMP Configuration Command SetConfiguring SNMP Notification ParametersSecureStack B2 Configuration Guide 4-594.3.7.6 clear snmp notifyfilterUse this c

Page 166 - 3.5.2 LACP Terminology

SNMP Configuration Command SetConfiguring SNMP Notification Parameters4-60 SecureStack B2 Configuration Guide4.3.7.7 show snmp notifyprofileUse this c

Page 167

SNMP Configuration Command SetConfiguring SNMP Notification ParametersSecureStack B2 Configuration Guide 4-614.3.7.8 set snmp notifyprofileUse this co

Page 168 - Configuring Link Aggregation

Related DocumentsSecureStack B2 Configuration Guide xxiiiRELATED DOCUMENTSThe following Enterasys Networks documents may help you to set up, control,

Page 169

SNMP Configuration Command SetConfiguring SNMP Notification Parameters4-62 SecureStack B2 Configuration Guide4.3.7.9 clear snmp notifyprofileUse this

Page 170 - 3.5.4.1 set lacp

SNMP Configuration Command SetCreating a Basic SNMP Trap ConfigurationSecureStack B2 Configuration Guide 4-634.3.8 Creating a Basic SNMP Trap Configur

Page 171 - 3.5.4.2 show lacp

SNMP Configuration Command SetCreating a Basic SNMP Trap Configuration4-64 SecureStack B2 Configuration GuideExampleThis example shows how to: • Creat

Page 172

SNMP Configuration Command SetCreating a Basic SNMP Trap ConfigurationSecureStack B2 Configuration Guide 4-654. Verifies that the v2ExampleParams desc

Page 173 - 3.5.4.3 set lacp asyspri

SNMP Configuration Command SetCreating a Basic SNMP Trap Configuration4-66 SecureStack B2 Configuration Guide

Page 174 - 3.5.4.4 set lacp aadminkey

SecureStack B2 Configuration Guide 5-15Spanning Tree ConfigurationThis chapter describes the Spanning Tree Configuration set of commands and how to us

Page 175 - 3.5.4.5 clear lacp

Spanning Tree Configuration SummarySpanning Tree Features5-2 SecureStack B2 Configuration Guideonly if the forwarding link goes down. MSTP assigns eac

Page 176 - 3.5.4.6 set lacp static

Spanning Tree Configuration Command SetProcess Overview: Spanning Tree ConfigurationSecureStack B2 Configuration Guide 5-35.1.3 Process Overview: Span

Page 177 - 3.5.4.7 clear lacp static

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-4 SecureStack B2 Configuration Guide• show spantree mstm

Page 178 - 3.5.4.8 show port lacp

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-55.2.1.1 show spantre

Page 179

Related Documentsxxiv SecureStack B2 Configuration GuideCaution: Contains information essential to avoid damage to the equipment.Precaución: Contiene

Page 180 - 3.5.4.9 set port lacp

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-6 SecureStack B2 Configuration GuideExampleThis example

Page 181 - (Section 3.5.4.3)

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-7Root Forward Delay A

Page 182

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-8 SecureStack B2 Configuration Guide5.2.1.2 set spantree

Page 183 - 3.5.4.10 clear port lacp

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-95.2.1.3 show spantre

Page 184

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-10 SecureStack B2 Configuration Guide5.2.1.4 set spantre

Page 185

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-115.2.1.5 clear spant

Page 186 - 3.5.5.1 show broadcast

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-12 SecureStack B2 Configuration Guide5.2.1.6 show spantr

Page 187 - 3.5.5.2 set broadcast

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-135.2.1.7 set spantre

Page 188

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-14 SecureStack B2 Configuration Guide5.2.1.8 clear spant

Page 189 - SNMP Configuration

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-155.2.1.9 show spantr

Page 190 - 4.1.2 SNMPv3

SecureStack B2 Configuration Guide 1-11IntroductionThis chapter provides an overview of the SecureStack B2’s unique features and functionality, an ove

Page 191 - SNMP Configuration Summary

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-16 SecureStack B2 Configuration Guide5.2.1.10 set spantr

Page 192

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-175.2.1.11 clear span

Page 193

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-18 SecureStack B2 Configuration Guide5.2.1.12 show spant

Page 194

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-195.2.1.13 show spant

Page 195 - 4.3.1.1 show snmp engineid

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-20 SecureStack B2 Configuration Guide5.2.1.14 set spantr

Page 196 - 4.3.1.2 show snmp counters

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-215.2.1.15 clear span

Page 197

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-22 SecureStack B2 Configuration Guide5.2.1.16 set spantr

Page 198

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-235.2.1.17 clear span

Page 199

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-24 SecureStack B2 Configuration Guide5.2.1.18 set spantr

Page 200

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-255.2.1.19 clear span

Page 201

Device Management Methods1-2 SecureStack B2 Configuration Guide• Configure ports to prioritize and assign a VLAN or Class of Service to incoming frame

Page 202

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-26 SecureStack B2 Configuration Guide5.2.1.20 set spantr

Page 203 - 4.3.2.1 show snmp user

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-275.2.1.21 clear span

Page 204

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge Parameters5-28 SecureStack B2 Configuration Guide5.2.1.22 set spantr

Page 205 - 4.3.2.2 set snmp user

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Bridge ParametersSecureStack B2 Configuration Guide 5-295.2.1.23 clear span

Page 206 - 4.3.2.3 clear snmp user

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-30 SecureStack B2 Configuration Guide5.2.2 Reviewing and S

Page 207 - 4.3.2.4 show snmp group

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port ParametersSecureStack B2 Configuration Guide 5-315.2.2.1 set spantree

Page 208

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-32 SecureStack B2 Configuration Guide5.2.2.2 clear spantre

Page 209 - 4.3.2.5 set snmp group

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port ParametersSecureStack B2 Configuration Guide 5-335.2.2.3 show spantree

Page 210 - 4.3.2.6 clear snmp group

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-34 SecureStack B2 Configuration Guide5.2.2.4 set spantree

Page 211 - 4.3.2.7 show snmp community

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port ParametersSecureStack B2 Configuration Guide 5-355.2.2.5 clear spantre

Page 212 - 4.3.2.8 set snmp community

Getting HelpSecureStack B2 Configuration Guide 1-31.3 GETTING HELPFor additional support related to this device or document, contact Enterasys Network

Page 213 - 4.3.2.9 clear snmp community

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-36 SecureStack B2 Configuration Guide5.2.2.6 show spantree

Page 214

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port ParametersSecureStack B2 Configuration Guide 5-375.2.2.7 set spantree

Page 215 - 4.3.3.1 show snmp access

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-38 SecureStack B2 Configuration Guide5.2.2.8 clear spantre

Page 216

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port ParametersSecureStack B2 Configuration Guide 5-395.2.2.9 show spantree

Page 217

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-40 SecureStack B2 Configuration Guide5.2.2.10 set spantree

Page 218 - 4.3.3.2 set snmp access

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port ParametersSecureStack B2 Configuration Guide 5-415.2.2.11 clear spantr

Page 219

Spanning Tree Configuration Command SetReviewing and Setting Spanning Tree Port Parameters5-42 SecureStack B2 Configuration Guide

Page 220 - 4.3.3.3 clear snmp access

SecureStack B2 Configuration Guide 6-16802.1Q VLAN ConfigurationThis chapter describes the SecureStack system’s capabilities to implement 802.1Q virtu

Page 221

VLAN Configuration SummaryPort Assignment Scheme6-2 SecureStack B2 Configuration Guide6.1 VLAN CONFIGURATION SUMMARYVirtual LANs allow the network adm

Page 222 - 4.3.4.1 show snmp view

Process Overview: 802.1Q VLAN ConfigurationPort String Syntax Used in the CLISecureStack B2 Configuration Guide 6-36.2 PROCESS OVERVIEW: 802.1Q VLAN C

Page 223

iNoticeEnterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site witho

Page 224 - 4.3.4.2 show snmp context

Getting Help1-4 SecureStack B2 Configuration Guide

Page 225 - 4.3.4.3 set snmp view

VLAN Configuration Command SetReviewing Existing VLANs6-4 SecureStack B2 Configuration Guide6.3 VLAN CONFIGURATION COMMAND SET6.3.1 Reviewing Existing

Page 226 - 4.3.4.4 clear snmp view

VLAN Configuration Command SetReviewing Existing VLANsSecureStack B2 Configuration Guide 6-56.3.1.1 show vlanUse this command to display all informati

Page 227

VLAN Configuration Command SetReviewing Existing VLANs6-6 SecureStack B2 Configuration Guideare listed as untagged ports. There are no forbidden ports

Page 228

VLAN Configuration Command SetCreating and Naming Static VLANsSecureStack B2 Configuration Guide 6-76.3.2 Creating and Naming Static VLANsPurposeTo cr

Page 229

VLAN Configuration Command SetCreating and Naming Static VLANs6-8 SecureStack B2 Configuration Guide6.3.2.1 set vlanUse this command to create a new s

Page 230

VLAN Configuration Command SetCreating and Naming Static VLANsSecureStack B2 Configuration Guide 6-96.3.2.2 set vlan nameUse this command to set or ch

Page 231 - 4.3.5.2 set snmp targetparams

VLAN Configuration Command SetCreating and Naming Static VLANs6-10 SecureStack B2 Configuration Guide6.3.2.3 clear vlanUse this command to remove a st

Page 232

VLAN Configuration Command SetCreating and Naming Static VLANsSecureStack B2 Configuration Guide 6-116.3.2.4 clear vlan nameUse this command to remove

Page 233

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress Filtering6-12 SecureStack B2 Configuration Guide6.3.3 Assigning Port VLAN ID

Page 234

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress FilteringSecureStack B2 Configuration Guide 6-136.3.3.1 show port vlanUse th

Page 235 - 4.3.6.1 show snmp targetaddr

SecureStack B2 Configuration Guide 2-12Startup and General ConfigurationThis chapter describes factory default settings and the Startup and General Co

Page 236

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress Filtering6-14 SecureStack B2 Configuration Guide6.3.3.2 set port vlanUse thi

Page 237 - 4.3.6.2 set snmp targetaddr

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress FilteringSecureStack B2 Configuration Guide 6-156.3.3.3 clear port vlanUse t

Page 238 - TrapSink

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress Filtering6-16 SecureStack B2 Configuration Guide6.3.3.4 show port ingress fi

Page 239 - 4.3.6.3 clear snmp targetaddr

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress FilteringSecureStack B2 Configuration Guide 6-176.3.3.5 set port ingress fil

Page 240

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress Filtering6-18 SecureStack B2 Configuration Guide6.3.3.6 show port discardUse

Page 241 - 4.3.7.1 show snmp notify

VLAN Configuration Command SetAssigning Port VLAN IDs (PVIDs) and Ingress FilteringSecureStack B2 Configuration Guide 6-196.3.3.7 set port discardUse

Page 242

VLAN Configuration Command SetConfiguring the VLAN Egress List6-20 SecureStack B2 Configuration Guide6.3.3.8 clear port discardUse this command to res

Page 243 - 4.3.7.2 set snmp notify

VLAN Configuration Command SetConfiguring the VLAN Egress ListSecureStack B2 Configuration Guide 6-21CommandsThe commands used to configure VLAN egres

Page 244 - About SNMP Notify Filters

VLAN Configuration Command SetConfiguring the VLAN Egress List6-22 SecureStack B2 Configuration Guide6.3.4.1 show port egressUse this command to displ

Page 245

VLAN Configuration Command SetConfiguring the VLAN Egress ListSecureStack B2 Configuration Guide 6-236.3.4.2 set vlan forbiddenUse this command to pre

Page 246 - 4.3.7.5 set snmp notifyfilter

Startup and General Configuration SummaryFactory Default Settings2-2 SecureStack B2 Configuration GuideDoes not apply to MATRIX E7.EAPOL authenticatio

Page 247

VLAN Configuration Command SetConfiguring the VLAN Egress List6-24 SecureStack B2 Configuration Guide6.3.4.3 set vlan egressUse this command to add po

Page 248

VLAN Configuration Command SetConfiguring the VLAN Egress ListSecureStack B2 Configuration Guide 6-25This example shows how to forbid Fast Ethernet po

Page 249 - and associate a target

VLAN Configuration Command SetConfiguring the VLAN Egress List6-26 SecureStack B2 Configuration Guide6.3.4.4 clear vlan egressUse this command to remo

Page 250

VLAN Configuration Command SetSetting the Host VLANSecureStack B2 Configuration Guide 6-276.3.5 Setting the Host VLANPurposeTo configure a host VLAN t

Page 251

VLAN Configuration Command SetSetting the Host VLAN6-28 SecureStack B2 Configuration Guide6.3.5.1 show host vlanUse this command to display the curren

Page 252

VLAN Configuration Command SetSetting the Host VLANSecureStack B2 Configuration Guide 6-296.3.5.2 set host vlanUse this command to assign host status

Page 253

VLAN Configuration Command SetSetting the Host VLAN6-30 SecureStack B2 Configuration Guide6.3.5.3 clear host vlanUse this command to reset the host VL

Page 254

VLAN Configuration Command SetCreating a Secure Management VLANSecureStack B2 Configuration Guide 6-316.3.6 Creating a Secure Management VLANIf the Se

Page 255 - Spanning Tree Configuration

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)6-32 SecureStack B2 Configuration Guide6.3.7 Enabling/Disabling

Page 256 - 5.1.2 Spanning Tree Features

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)SecureStack B2 Configuration Guide 6-33Figure 6-1 Example of VL

Page 257

Startup and General Configuration SummaryFactory Default SettingsSecureStack B2 Configuration Guide 2-3Password aging Disabled.Password history No pas

Page 258

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)6-34 SecureStack B2 Configuration GuideCommandsThe commands use

Page 259 - 5.2.1.1 show spantree stats

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)SecureStack B2 Configuration Guide 6-356.3.7.1 show gvrp Use th

Page 260

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)6-36 SecureStack B2 Configuration Guide6.3.7.2 show garp timerU

Page 261

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)SecureStack B2 Configuration Guide 6-37Table 6-4 provides an ex

Page 262 - 5.2.1.2 set spantree

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)6-38 SecureStack B2 Configuration Guide6.3.7.3 set gvrpUse this

Page 263 - 5.2.1.3 show spantree version

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)SecureStack B2 Configuration Guide 6-396.3.7.4 clear gvrpUse th

Page 264 - 5.2.1.4 set spantree version

VLAN Configuration Command SetEnabling/Disabling GVRP (GARP VLAN Registration Protocol)6-40 SecureStack B2 Configuration Guide6.3.7.5 set garp timerUs

Page 265

SecureStack B2 Configuration Guide 7-17Differentiated Services ConfigurationThis chapter describes the Differentiated Services (Diffserv) set of comma

Page 266

Differentiated Services Configuration Command SetGlobally Enabling or Disabling Diffserv7-2 SecureStack B2 Configuration Guide7.3 DIFFERENTIATED SERVI

Page 267 - 5.2.1.7 set spantree msti

Differentiated Services Configuration Command SetGlobally Enabling or Disabling DiffservSecureStack B2 Configuration Guide 7-37.3.1.1 set diffserv adm

Page 268 - 5.2.1.8 clear spantree msti

Startup and General Configuration SummaryFactory Default Settings2-4 SecureStack B2 Configuration GuideSpanning Tree edge port delayEnabled. Spanning

Page 269 - 5.2.1.9 show spantree mstmap

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching Conditions7-4 SecureStack B2 Configuration Guide7.3.2 Creating

Page 270 - 5.2.1.10 set spantree mstmap

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching ConditionsSecureStack B2 Configuration Guide 7-57.3.2.1 show d

Page 271

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching Conditions7-6 SecureStack B2 Configuration Guide7.3.2.2 show d

Page 272

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching ConditionsSecureStack B2 Configuration Guide 7-77.3.2.3 set cl

Page 273

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching Conditions7-8 SecureStack B2 Configuration Guide7.3.2.4 set di

Page 274

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching ConditionsSecureStack B2 Configuration Guide 7-97.3.2.5 set di

Page 275

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching Conditions7-10 SecureStack B2 Configuration GuideClass matches

Page 276

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching ConditionsSecureStack B2 Configuration Guide 7-11Command Defau

Page 277

Differentiated Services Configuration Command SetCreating Diffserv Classes and Matching Conditions7-12 SecureStack B2 Configuration GuideCommand TypeS

Page 278 - 5.2.1.18 set spantree hello

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning ClassesSecureStack B2 Configuration Guide 7-137.3.

Page 279 - 5.2.1.19 clear spantree hello

Startup and General Configuration SummaryCLI “Command Defaults” DescriptionsSecureStack B2 Configuration Guide 2-52.1.2 CLI “Command Defaults” Descrip

Page 280 - 5.2.1.20 set spantree maxage

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning Classes7-14 SecureStack B2 Configuration Guide• se

Page 281

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning ClassesSecureStack B2 Configuration Guide 7-157.3.

Page 282

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning Classes7-16 SecureStack B2 Configuration Guide7.3.

Page 283

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning ClassesSecureStack B2 Configuration Guide 7-177.3.

Page 284

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning Classes7-18 SecureStack B2 Configuration Guide7.3.

Page 285

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning ClassesSecureStack B2 Configuration Guide 7-197.3.

Page 286

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning Classes7-20 SecureStack B2 Configuration Guide7.3.

Page 287 - 5.2.2.3 show spantree portpri

Differentiated Services Configuration Command SetConfiguring Diffserv Policy Profiles and Assigning ClassesSecureStack B2 Configuration Guide 7-217.3.

Page 288 - 5.2.2.4 set spantree portpri

Differentiated Services Configuration Command SetAssigning Policy Profiles to Service Ports7-22 SecureStack B2 Configuration Guide7.3.4 Assigning Poli

Page 289

Differentiated Services Configuration Command SetAssigning Policy Profiles to Service PortsSecureStack B2 Configuration Guide 7-237.3.4.1 show diffser

Page 290

Startup and General Configuration SummaryUsing WebView2-6 SecureStack B2 Configuration Guide2.1.4 Using WebViewBy default WebView (Enterasys Networks’

Page 291

Differentiated Services Configuration Command SetAssigning Policy Profiles to Service Ports7-24 SecureStack B2 Configuration Guide7.3.4.2 show diffser

Page 292

Differentiated Services Configuration Command SetAssigning Policy Profiles to Service PortsSecureStack B2 Configuration Guide 7-257.3.4.3 set diffserv

Page 293

Differentiated Services Configuration Command SetAssigning Policy Profiles to Service Ports7-26 SecureStack B2 Configuration Guide

Page 294

SecureStack B2 Configuration Guide 8-18Port Priority and Rate LimitingConfigurationThis chapter describes the Port Priority and Rate Limiting set of c

Page 295

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Priority8-2 SecureStack B2 Configuration Guide8.3 PORT PRIORITY AND RATE LIM

Page 296

Port Priority and Rate Limiting Configuration Command SetConfiguring Port PrioritySecureStack B2 Configuration Guide 8-38.3.1.1 show port priorityUse

Page 297 - 802.1Q VLAN Configuration

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Priority8-4 SecureStack B2 Configuration Guide8.3.1.2 set port priorityUse t

Page 298 - 6.1.1 Port Assignment Scheme

Port Priority and Rate Limiting Configuration Command SetConfiguring Port PrioritySecureStack B2 Configuration Guide 8-58.3.1.3 clear port priorityUse

Page 299

Port Priority and Rate Limiting Configuration Command SetConfiguring Priority to Transmit Queue Mapping8-6 SecureStack B2 Configuration Guide8.3.2 Con

Page 300 - • show vlan (Section 6.3.1.1)

Port Priority and Rate Limiting Configuration Command SetConfiguring Priority to Transmit Queue MappingSecureStack B2 Configuration Guide 8-78.3.2.1 s

Page 301 - 6.3.1.1 show vlan

Startup and General Configuration SummaryStarting and Navigating the Command Line InterfaceSecureStack B2 Configuration Guide 2-72.1.6 Starting and Na

Page 302

Port Priority and Rate Limiting Configuration Command SetConfiguring Priority to Transmit Queue Mapping8-8 SecureStack B2 Configuration Guide8.3.2.2 s

Page 303

Port Priority and Rate Limiting Configuration Command SetConfiguring Priority to Transmit Queue MappingSecureStack B2 Configuration Guide 8-98.3.2.3 c

Page 304 - 6.3.2.1 set vlan

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate Limiting8-10 SecureStack B2 Configuration Guide8.3.3 Configurin

Page 305 - 6.3.2.2 set vlan name

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate LimitingSecureStack B2 Configuration Guide 8-118.3.3.1 show por

Page 306 - 6.3.2.3 clear vlan

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate Limiting8-12 SecureStack B2 Configuration GuideTable 8-1 show p

Page 307 - 6.3.2.4 clear vlan name

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate LimitingSecureStack B2 Configuration Guide 8-138.3.3.2 set port

Page 308

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate Limiting8-14 SecureStack B2 Configuration GuideExampleThis exam

Page 309 - 6.3.3.1 show port vlan

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate LimitingSecureStack B2 Configuration Guide 8-158.3.3.3 clear po

Page 310 - 6.3.3.2 set port vlan

Port Priority and Rate Limiting Configuration Command SetConfiguring Port Traffic Rate Limiting8-16 SecureStack B2 Configuration Guide

Page 311 - 6.3.3.3 clear port vlan

SecureStack B2 Configuration Guide 9-19IGMP ConfigurationThis chapter describes the IGMP Configuration set of commands and how to use them. 9.1 ABOUT

Page 312

Startup and General Configuration SummaryStarting and Navigating the Command Line Interface2-8 SecureStack B2 Configuration Guide2.1.6.3 Logging in wi

Page 313

IGMP Configuration SummaryEnabling / Disabling IGMP9-2 SecureStack B2 Configuration GuideThe purpose of IP multicast group management is to optimize a

Page 314 - 6.3.3.6 show port discard

IGMP Configuration Command SetEnabling / Disabling IGMPSecureStack B2 Configuration Guide 9-39.4.1.1 show igmpsnoopingUse this command to display IGMP

Page 315 - 6.3.3.7 set port discard

IGMP Configuration Command SetEnabling / Disabling IGMP9-4 SecureStack B2 Configuration Guide9.4.1.2 set igmpsnooping adminmodeUse this command to ena

Page 316 - 6.3.3.8 clear port discard

IGMP Configuration Command SetEnabling / Disabling IGMPSecureStack B2 Configuration Guide 9-59.4.1.3 set igmpsnooping interfacemodeUse this command to

Page 317

IGMP Configuration Command SetConfiguring IGMP9-6 SecureStack B2 Configuration Guide9.4.2 Configuring IGMP PurposeTo display and set IGMP configuratio

Page 318 - 6.3.4.1 show port egress

IGMP Configuration Command SetConfiguring IGMPSecureStack B2 Configuration Guide 9-79.4.2.1 set igmpsnooping groupmembershipintervalUse this command t

Page 319 - 6.3.4.2 set vlan forbidden

IGMP Configuration Command SetConfiguring IGMP9-8 SecureStack B2 Configuration Guide9.4.2.2 set igmpsnooping maxresponseUse this command to configure

Page 320 - 6.3.4.3 set vlan egress

IGMP Configuration Command SetConfiguring IGMPSecureStack B2 Configuration Guide 9-99.4.2.3 set igmpsnooping mcrtrexpiretimeUse this command to config

Page 321

IGMP Configuration Command SetConfiguring IGMP9-10 SecureStack B2 Configuration Guide9.4.2.4 show igmpsnooping mfdbUse this command to display multica

Page 322 - 6.3.4.4 clear vlan egress

IGMP Configuration Command SetConfiguring IGMPSecureStack B2 Configuration Guide 9-119.4.2.5 clear igmpsnoopingUse this command to clear all IGMP snoo

Page 323 - 6.3.5 Setting the Host VLAN

Startup and General Configuration SummaryGetting Help with CLI SyntaxSecureStack B2 Configuration Guide 2-9Figure 2-2 SecureStack B2 Startup Screen2.1

Page 324 - 6.3.5.1 show host vlan

IGMP Configuration Command SetConfiguring IGMP9-12 SecureStack B2 Configuration Guide

Page 325 - 6.3.5.2 set host vlan

SecureStack B2 Configuration Guide 10-110Logging and Network ManagementThis chapter describes switch-related logging and network management commands a

Page 326 - 6.3.5.3 clear host vlan

Logging And Network Management Command SetConfiguring System Logging10-2 SecureStack B2 Configuration Guide10.2 LOGGING AND NETWORK MANAGEMENT COMMAND

Page 327

Logging And Network Management Command SetConfiguring System LoggingSecureStack B2 Configuration Guide 10-310.2.1.1 show logging server Use this comma

Page 328 - Purpose

Logging And Network Management Command SetConfiguring System Logging10-4 SecureStack B2 Configuration Guide10.2.1.2 set logging serverUse this command

Page 329 - 1H152-51

Logging And Network Management Command SetConfiguring System LoggingSecureStack B2 Configuration Guide 10-5Command Defaults• If ip- addr is not specif

Page 330

Logging And Network Management Command SetConfiguring System Logging10-6 SecureStack B2 Configuration Guide10.2.1.3 clear logging serverUse this comma

Page 331 - 6.3.7.1 show gvrp

Logging And Network Management Command SetConfiguring System LoggingSecureStack B2 Configuration Guide 10-710.2.1.4 show logging defaultUse this comma

Page 332 - 6.3.7.2 show garp timer

Logging And Network Management Command SetConfiguring System Logging10-8 SecureStack B2 Configuration Guide10.2.1.5 set logging defaultUse this comman

Page 333

Logging And Network Management Command SetConfiguring System LoggingSecureStack B2 Configuration Guide 10-910.2.1.6 clear logging defaultUse this comm

Page 334 - 6.3.7.3 set gvrp

NoticeiiEnterasys Networks, Inc.Firmware License AgreementBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGREEMENT.This

Page 335 - 6.3.7.4 clear gvrp

Startup and General Configuration SummaryGetting Help with CLI Syntax2-10 SecureStack B2 Configuration GuideEntering a question mark (?) without a spa

Page 336 - 6.3.7.5 set garp timer

Logging And Network Management Command SetConfiguring System Logging10-10 SecureStack B2 Configuration Guide10.2.1.7 show logging localUse this comman

Page 337 - CONFIGURATION

Logging And Network Management Command SetConfiguring System LoggingSecureStack B2 Configuration Guide 10-1110.2.1.8 set logging localUse this command

Page 338

Logging And Network Management Command SetConfiguring System Logging10-12 SecureStack B2 Configuration Guide10.2.1.9 clear logging localUse this comma

Page 339 - {enable

Logging And Network Management Command SetConfiguring System LoggingSecureStack B2 Configuration Guide 10-1310.2.1.10 show logging bufferUse this comm

Page 340

Logging And Network Management Command SetMonitoring Network Events and Status10-14 SecureStack B2 Configuration Guide10.2.2 Monitoring Network Events

Page 341 - 7.3.2.1 show diffserv info

Logging And Network Management Command SetMonitoring Network Events and StatusSecureStack B2 Configuration Guide 10-1510.2.2.1 historyUse this command

Page 342 - 7.3.2.2 show diffserv class

Logging And Network Management Command SetMonitoring Network Events and Status10-16 SecureStack B2 Configuration Guide10.2.2.2 show historyUse this co

Page 343 - 7.3.2.3 set class create

Logging And Network Management Command SetMonitoring Network Events and StatusSecureStack B2 Configuration Guide 10-1710.2.2.3 set historyUse this com

Page 344

Logging And Network Management Command SetMonitoring Network Events and Status10-18 SecureStack B2 Configuration Guide10.2.2.4 pingUse this command to

Page 345

Logging And Network Management Command SetMonitoring Network Events and StatusSecureStack B2 Configuration Guide 10-19This example shows how to ping I

Page 346

Startup and General Configuration SummaryAbbreviating and Completing CommandsSecureStack B2 Configuration Guide 2-112.1.8 Abbreviating and Completing

Page 347

Logging And Network Management Command SetMonitoring Network Events and Status10-20 SecureStack B2 Configuration Guide10.2.2.5 show usersUse this comm

Page 348

Logging And Network Management Command SetMonitoring Network Events and StatusSecureStack B2 Configuration Guide 10-2110.2.2.6 disconnectUse this comm

Page 349

Logging And Network Management Command SetManaging Switch Network Addresses and Routes10-22 SecureStack B2 Configuration Guide10.2.3 Managing Switch N

Page 350 - Section 7.3.3.7)

Logging And Network Management Command SetManaging Switch Network Addresses and RoutesSecureStack B2 Configuration Guide 10-2310.2.3.1 show arpUse thi

Page 351 - 7.3.3.1 show diffserv policy

Logging And Network Management Command SetManaging Switch Network Addresses and Routes10-24 SecureStack B2 Configuration Guide10.2.3.2 clear arpUse th

Page 352

Logging And Network Management Command SetManaging Switch Network Addresses and RoutesSecureStack B2 Configuration Guide 10-2510.2.3.3 show mac Use th

Page 353 - Section 7.3.4.3

Logging And Network Management Command SetManaging Switch Network Addresses and Routes10-26 SecureStack B2 Configuration GuideExampleThis example show

Page 354

Logging And Network Management Command SetManaging Switch Network Addresses and RoutesSecureStack B2 Configuration Guide 10-2710.2.3.4 show mac agetim

Page 355 - associate to this policy

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-28 SecureStack B2 Configuration Guide10.2.4 Configuring Si

Page 356

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-2910.2.4.1 show sntpUse

Page 357

Startup and General Configuration SummaryBasic Line Editing Commands2-12 SecureStack B2 Configuration GuideCtrl+N Scroll to next command in command hi

Page 358

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-30 SecureStack B2 Configuration GuideTable 10-3 show sntp

Page 359

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-3110.2.4.2 set sntp cli

Page 360

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-32 SecureStack B2 Configuration Guide10.2.4.3 clear sntp c

Page 361 - 7.3.4.3 set diffserv service

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-3310.2.4.4 set sntp ser

Page 362

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-34 SecureStack B2 Configuration Guide10.2.4.5 clear sntp s

Page 363 - Configuration

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-3510.2.4.6 set sntp bro

Page 364 - COMMAND SET

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-36 SecureStack B2 Configuration Guide10.2.4.7 clear sntp b

Page 365 - 8.3.1.1 show port priority

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-3710.2.4.8 set sntp pol

Page 366 - 8.3.1.2 set port priority

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-38 SecureStack B2 Configuration Guide10.2.4.9 clear sntp p

Page 367 - 8.3.1.3 clear port priority

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-3910.2.4.10 set sntp po

Page 368

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-132.1.10 GENERAL CONFIGURATION COMMAND

Page 369

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-40 SecureStack B2 Configuration Guide10.2.4.11 clear sntp

Page 370 - • 1000Base-X - 8

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)SecureStack B2 Configuration Guide 10-4110.2.4.12 set sntp po

Page 371

Logging And Network Management Command SetConfiguring Simple Network Time Protocol (SNTP)10-42 SecureStack B2 Configuration Guide10.2.4.13 clear sntp

Page 372

Logging And Network Management Command SetConfiguring Node AliasesSecureStack B2 Configuration Guide 10-4310.2.5 Configuring Node AliasesPurposeTo rev

Page 373 - 8.3.3.1 show port ratelimit

Logging And Network Management Command SetConfiguring Node Aliases10-44 SecureStack B2 Configuration Guide10.2.5.1 show nodealias configUse this comma

Page 374

Logging And Network Management Command SetConfiguring Node AliasesSecureStack B2 Configuration Guide 10-4510.2.5.2 set nodealiasUse this command to en

Page 375 - 8.3.3.2 set port ratelimit

Logging And Network Management Command SetConfiguring Node Aliases10-46 SecureStack B2 Configuration Guide10.2.5.3 clear nodealias configUse this comm

Page 376 - This example shows how to:

SecureStack B2 Configuration Guide 11-111Security ConfigurationThis chapter describes the Security Configuration set of commands and how to use them.1

Page 377 - 8.3.3.3 clear port ratelimit

Process Overview: Security Configuration11-2 SecureStack B2 Configuration Guide• MAC Locking – locks a port to one or more MAC addresses, preventing c

Page 378

Security Configuration Command SetConfiguring RADIUSSecureStack B2 Configuration Guide 11-311.3 SECURITY CONFIGURATION COMMAND SET11.3.1 Configuring R

Page 379 - IGMP Configuration

Startup and General Configuration SummaryGeneral Configuration Command Set2-14 SecureStack B2 Configuration Guide3. The management election process us

Page 380 - Enabling / Disabling IGMP

Security Configuration Command SetConfiguring RADIUS11-4 SecureStack B2 Configuration Guide11.3.1.1 show radiusUse this command to display the current

Page 381 - 9.4.1.1 show igmpsnooping

Security Configuration Command SetConfiguring RADIUSSecureStack B2 Configuration Guide 11-5Table 11-1 show radius Output DetailsOutput What It Display

Page 382

Security Configuration Command SetConfiguring RADIUS11-6 SecureStack B2 Configuration Guide11.3.1.2 set radiusUse this command to enable, disable, or

Page 383

Security Configuration Command SetConfiguring RADIUSSecureStack B2 Configuration Guide 11-7This example shows how to set the RADIUS timeout to 5 secon

Page 384 - 9.4.2 Configuring IGMP

Security Configuration Command SetConfiguring RADIUS11-8 SecureStack B2 Configuration Guide11.3.1.3 clear radiusUse this command to clear RADIUS serve

Page 385 - Configuring IGMP

Security Configuration Command SetConfiguring RADIUSSecureStack B2 Configuration Guide 11-911.3.1.4 show radius accountingUse this command to display

Page 386

Security Configuration Command SetConfiguring RADIUS11-10 SecureStack B2 Configuration Guide11.3.1.5 set radius accountingUse this command to configur

Page 387

Security Configuration Command SetConfiguring RADIUSSecureStack B2 Configuration Guide 11-11ExamplesThis example shows how to enable the RADIUS accoun

Page 388

Security Configuration Command SetConfiguring RADIUS11-12 SecureStack B2 Configuration Guide11.3.1.6 clear radius accountingUse this command to clear

Page 389 - 9.4.2.5 clear igmpsnooping

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-1311.3.2 Configuring 802.1X AuthenticationPur

Page 390

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-15Installing a Previously-Configured Sy

Page 391

Security Configuration Command SetConfiguring 802.1X Authentication11-14 SecureStack B2 Configuration Guide11.3.2.1 show dot1xUse this command to disp

Page 392

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-15This example shows how to display authentic

Page 393 - 10.2.1.1 show logging server

Security Configuration Command SetConfiguring 802.1X Authentication11-16 SecureStack B2 Configuration GuideThis example shows how to display the statu

Page 394 - 10.2.1.2 set logging server

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-1711.3.2.2 show dot1x auth-configUse this com

Page 395 - Configuring System Logging

Security Configuration Command SetConfiguring 802.1X Authentication11-18 SecureStack B2 Configuration GuideCommand ModeRead-Only.Command Defaults• If

Page 396 - 10.2.1.3 clear logging server

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-1911.3.2.3 set dot1xUse this command to enabl

Page 397 - 10.2.1.4 show logging default

Security Configuration Command SetConfiguring 802.1X Authentication11-20 SecureStack B2 Configuration Guide11.3.2.4 set dot1x auth-configUse this comm

Page 398 - 10.2.1.5 set logging default

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-21Command ModeRead-Write.Command DefaultsIf p

Page 399

Security Configuration Command SetConfiguring 802.1X Authentication11-22 SecureStack B2 Configuration Guide11.3.2.5 clear dot1x auth-configUse this co

Page 400 - 10.2.1.7 show logging local

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-23ExamplesThis example shows how to reset the

Page 401 - 10.2.1.8 set logging local

Startup and General Configuration SummaryGeneral Configuration Command Set2-16 SecureStack B2 Configuration GuidePurpose To review, individually confi

Page 402 - 10.2.1.9 clear logging local

Security Configuration Command SetConfiguring 802.1X Authentication11-24 SecureStack B2 Configuration Guide11.3.2.6 show eapolUse this command to disp

Page 403 - 10.2.1.10 show logging buffer

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-25Authentication StateCurrent EAPOL authentic

Page 404

Security Configuration Command SetConfiguring 802.1X Authentication11-26 SecureStack B2 Configuration GuideAuthentication ModeMode enabling network ac

Page 405 - 10.2.2.1 history

Security Configuration Command SetConfiguring 802.1X AuthenticationSecureStack B2 Configuration Guide 11-2711.3.2.7 set eapolUse this command to enabl

Page 406 - 10.2.2.2 show history

Security Configuration Command SetConfiguring 802.1X Authentication11-28 SecureStack B2 Configuration Guide11.3.2.8 clear eapolUse this command to glo

Page 407 - 10.2.2.3 set history

Security Configuration Command SetConfiguring VLAN Authorization (RFC 3580)SecureStack B2 Configuration Guide 11-2911.3.3 Configuring VLAN Authorizati

Page 408 - 10.2.2.4 ping

Security Configuration Command SetConfiguring VLAN Authorization (RFC 3580)11-30 SecureStack B2 Configuration Guide11.3.3.1 set vlanauthorizationEnabl

Page 409

Security Configuration Command SetConfiguring VLAN Authorization (RFC 3580)SecureStack B2 Configuration Guide 11-3111.3.3.2 set vlanauthorization egre

Page 410 - 10.2.2.5 show users

Security Configuration Command SetConfiguring VLAN Authorization (RFC 3580)11-32 SecureStack B2 Configuration Guide11.3.3.3 clear vlanauthorizationRet

Page 411 - 10.2.2.6 disconnect

Security Configuration Command SetConfiguring VLAN Authorization (RFC 3580)SecureStack B2 Configuration Guide 11-3311.3.3.4 show vlanauthorizationDisp

Page 412

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-172.1.10.2 show switchUse this command

Page 413 - 10.2.3.1 show arp

Security Configuration Command SetConfiguring VLAN Authorization (RFC 3580)11-34 SecureStack B2 Configuration Guideoperational egressIf authentication

Page 414 - 10.2.3.2 clear arp

Security Configuration Command SetConfiguring MAC LockingSecureStack B2 Configuration Guide 11-3511.3.4 Configuring MAC LockingPurposeTo review, disab

Page 415 - 10.2.3.3 show mac

Security Configuration Command SetConfiguring MAC Locking11-36 SecureStack B2 Configuration Guide11.3.4.1 show maclockUse this command to display the

Page 416 - • learned

Security Configuration Command SetConfiguring MAC LockingSecureStack B2 Configuration Guide 11-37Table 11-4 show maclock Output DetailsOutput What It

Page 417 - 10.2.3.4 show mac agetime

Security Configuration Command SetConfiguring MAC Locking11-38 SecureStack B2 Configuration Guide11.3.4.2 show maclock stationsUse this command to dis

Page 418

Security Configuration Command SetConfiguring MAC LockingSecureStack B2 Configuration Guide 11-39Table 11-5 show maclock stations Output DetailsOutput

Page 419 - 10.2.4.1 show sntp

Security Configuration Command SetConfiguring MAC Locking11-40 SecureStack B2 Configuration Guide11.3.4.3 set maclock enableUse this command to enable

Page 420

Security Configuration Command SetConfiguring MAC LockingSecureStack B2 Configuration Guide 11-4111.3.4.4 set maclock disableUse this command to disab

Page 421 - 10.2.4.2 set sntp client

Security Configuration Command SetConfiguring MAC Locking11-42 SecureStack B2 Configuration Guide11.3.4.5 set maclock firstarrivalUse this command to

Page 422 - 10.2.4.3 clear sntp client

Security Configuration Command SetConfiguring MAC LockingSecureStack B2 Configuration Guide 11-4311.3.4.6 clear maclock firstarrivalUse this command t

Page 423 - 10.2.4.4 set sntp server

Startup and General Configuration SummaryGeneral Configuration Command Set2-18 SecureStack B2 Configuration GuideThis example shows how to display inf

Page 424 - 10.2.4.5 clear sntp server

Security Configuration Command SetConfiguring MAC Locking11-44 SecureStack B2 Configuration Guide11.3.4.7 set maclock trapUse this command to enable o

Page 425

Security Configuration Command SetConfiguring Secure Shell (SSH)SecureStack B2 Configuration Guide 11-4511.3.5 Configuring Secure Shell (SSH)PurposeTo

Page 426

Security Configuration Command SetConfiguring Secure Shell (SSH)11-46 SecureStack B2 Configuration Guide11.3.5.1 show ssh statusUse this command to di

Page 427

Security Configuration Command SetConfiguring Secure Shell (SSH)SecureStack B2 Configuration Guide 11-4711.3.5.2 set sshUse this command to enable, di

Page 428

Security Configuration Command SetConfiguring Secure Shell (SSH)11-48 SecureStack B2 Configuration Guide11.3.5.3 set ssh hostkeyUse this command to se

Page 429 - 10.2.4.10 set sntp poll-retry

SecureStack B2 Configuration Guide Index-1IndexNumerics802.1D 5-1802.1Q 6-1802.1s 5-1802.1w 5-1802.1x 11-6, 11-27AAdvertised Ability 3-23Aliasnode 10-

Page 430

IndexIndex-2 SecureStack B2 Configuration GuideFFlow Control 3-26Forbidden VLAN port 6-23GGetting Help 1-3GVRPenabling and disabling 6-38purpose of 6-

Page 431

IndexSecureStack B2 Configuration Guide Index-3Port Mirroring 3-29Port Priorityconfiguring 8-2Port Stringsyntax used in the CLI 3-2Port(s)assignment s

Page 432

IndexIndex-4 SecureStack B2 Configuration GuideVVersion Information 2-58VLANsassigning ingress filtering 6-17assigning port VLAN IDs 6-12authenticatio

Page 433

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-192.1.10.3 show switch switchtypeUse th

Page 434

Noticeiii3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of

Page 435 - 10.2.5.2 set nodealias

Startup and General Configuration SummaryGeneral Configuration Command Set2-20 SecureStack B2 Configuration Guide2.1.10.4 show switch stack-portsUse t

Page 436 - Configuring Node Aliases

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-212.1.10.5 set switchUse this command t

Page 437 - Security Configuration

Startup and General Configuration SummaryGeneral Configuration Command Set2-22 SecureStack B2 Configuration Guide2.1.10.6 set switch copy-swUse this c

Page 438

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-232.1.10.7 set switch descriptionUse th

Page 439 - 11.3.1 Configuring RADIUS

Startup and General Configuration SummaryGeneral Configuration Command Set2-24 SecureStack B2 Configuration Guide2.1.10.8 set switch movemanagementUse

Page 440 - 11.3.1.1 show radius

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-252.1.10.9 set switch memberUse this co

Page 441

Startup and General Configuration SummaryGeneral Configuration Command Set2-26 SecureStack B2 Configuration Guide2.1.10.10 clear switch memberUse this

Page 442 - 11.3.1.2 set radius

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-272.1.10.11 show snmp persistmodeUse th

Page 443 - Configuring RADIUS

Startup and General Configuration SummaryGeneral Configuration Command Set2-28 SecureStack B2 Configuration Guide2.1.10.12 set snmp persistmodeUse thi

Page 444 - 11.3.1.3 clear radius

Startup and General Configuration SummaryGeneral Configuration Command SetSecureStack B2 Configuration Guide 2-292.1.10.13 save configUse this command

Page 445

Noticeiv8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys a

Page 446 - • IP address

Startup and General Configuration SummarySetting User Accounts and Passwords2-30 SecureStack B2 Configuration Guide2.1.11 Setting User Accounts and Pa

Page 447

Startup and General Configuration SummarySetting User Accounts and PasswordsSecureStack B2 Configuration Guide 2-312.1.11.1 show system loginUse this

Page 448

Startup and General Configuration SummarySetting User Accounts and Passwords2-32 SecureStack B2 Configuration GuideAccess Access assigned to this user

Page 449

Startup and General Configuration SummarySetting User Accounts and PasswordsSecureStack B2 Configuration Guide 2-332.1.11.2 set system loginUse this c

Page 450 - 11.3.2.1 show dot1x

Startup and General Configuration SummarySetting User Accounts and Passwords2-34 SecureStack B2 Configuration Guide2.1.11.3 clear system loginUse this

Page 451

Startup and General Configuration SummarySetting User Accounts and PasswordsSecureStack B2 Configuration Guide 2-352.1.11.4 set passwordUse this comma

Page 452

Startup and General Configuration SummarySetting User Accounts and Passwords2-36 SecureStack B2 Configuration Guide2.1.11.5 set system password length

Page 453

Startup and General Configuration SummarySetting User Accounts and PasswordsSecureStack B2 Configuration Guide 2-372.1.11.6 set system password agingU

Page 454

Startup and General Configuration SummarySetting User Accounts and Passwords2-38 SecureStack B2 Configuration Guide2.1.11.7 set system password histor

Page 455 - 11.3.2.3 set dot1x

Startup and General Configuration SummarySetting User Accounts and PasswordsSecureStack B2 Configuration Guide 2-392.1.11.8 show system lockoutUse thi

Page 456

SecureStack B2 Configuration Guide vContentsFigures ...

Page 457

Startup and General Configuration SummarySetting User Accounts and Passwords2-40 SecureStack B2 Configuration Guide2.1.11.9 set system lockoutUse this

Page 458

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-412.1.12 Setting Basic Device PropertiesP

Page 459

Startup and General Configuration SummarySetting Basic Device Properties2-42 SecureStack B2 Configuration Guide• set logout (Section 2.1.12.21)• show

Page 460 - 11.3.2.6 show eapol

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-432.1.12.1 show ip addressUse this comman

Page 461

Startup and General Configuration SummarySetting Basic Device Properties2-44 SecureStack B2 Configuration Guide2.1.12.2 show ip protocolUse this comma

Page 462

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-452.1.12.3 set ip addressUse this command

Page 463 - 11.3.2.7 set eapol

Startup and General Configuration SummarySetting Basic Device Properties2-46 SecureStack B2 Configuration Guide2.1.12.4 show systemUse this command to

Page 464 - 11.3.2.8 clear eapol

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-47Table 2-5 show system Output DetailsOut

Page 465

Startup and General Configuration SummarySetting Basic Device Properties2-48 SecureStack B2 Configuration Guide2.1.12.5 show system hardwareUse this c

Page 466

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-492.1.12.6 set system enhancedbuffermodeU

Page 467

Contentsvi SecureStack B2 Configuration Guide2.1.10.4 show switch stack-ports ... 2-202.1.10.5 set switch ..

Page 468

Startup and General Configuration SummarySetting Basic Device Properties2-50 SecureStack B2 Configuration Guide2.1.12.7 show timeUse this command to d

Page 469

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-512.1.12.8 set timeUse this command to ch

Page 470 - VLAN id for ingress

Startup and General Configuration SummarySetting Basic Device Properties2-52 SecureStack B2 Configuration Guide2.1.12.9 show summertimeUse this comman

Page 471

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-532.1.12.10 set summertimeUse this comman

Page 472 - 11.3.4.1 show maclock

Startup and General Configuration SummarySetting Basic Device Properties2-54 SecureStack B2 Configuration Guide2.1.12.11 set summertime dateUse this c

Page 473

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-552.1.12.12 set summertime recurringUse t

Page 474

Startup and General Configuration SummarySetting Basic Device Properties2-56 SecureStack B2 Configuration Guide2.1.12.13 clear summertimeUse this comm

Page 475

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-572.1.12.14 set promptUse this command to

Page 476 - 11.3.4.3 set maclock enable

Startup and General Configuration SummarySetting Basic Device Properties2-58 SecureStack B2 Configuration Guide2.1.12.15 show versionUse this command

Page 477 - 11.3.4.4 set maclock disable

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-592.1.12.16 set system nameUse this comma

Page 478 - Configuring MAC Locking

ContentsSecureStack B2 Configuration Guide vii2.1.12.21 set logout ... 2-642.1.12.22 s

Page 479

Startup and General Configuration SummarySetting Basic Device Properties2-60 SecureStack B2 Configuration Guide2.1.12.17 set system locationUse this c

Page 480 - 11.3.4.7 set maclock trap

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-612.1.12.18 set system contactUse this co

Page 481

Startup and General Configuration SummarySetting Basic Device Properties2-62 SecureStack B2 Configuration Guide2.1.12.19 set lengthUse this command to

Page 482 - 11.3.5.1 show ssh status

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-632.1.12.20 show logoutUse this command t

Page 483 - 11.3.5.2 set ssh

Startup and General Configuration SummarySetting Basic Device Properties2-64 SecureStack B2 Configuration Guide2.1.12.21 set logout Use this command t

Page 484 - 11.3.5.3 set ssh hostkey

Startup and General Configuration SummarySetting Basic Device PropertiesSecureStack B2 Configuration Guide 2-652.1.12.22 show console Use this command

Page 485

Startup and General Configuration SummarySetting Basic Device Properties2-66 SecureStack B2 Configuration Guide2.1.12.23 set console baudUse this comm

Page 486

Startup and General Configuration SummaryConfiguring Power over Ethernet (PoE)SecureStack B2 Configuration Guide 2-672.1.13 Configuring Power over Eth

Page 487

Startup and General Configuration SummaryConfiguring Power over Ethernet (PoE)2-68 SecureStack B2 Configuration Guide2.1.13.1 show inlinepowerUse this

Page 488

Startup and General Configuration SummaryConfiguring Power over Ethernet (PoE)SecureStack B2 Configuration Guide 2-692.1.13.2 set inlinepower threshol

Comments to this Manuals

No comments