Enterasys Matrix N3 Installation Guide Page 38

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 37
Powering Up the Chassis
3-10 Chassis Setup
3.3 POWERING UP THE CHASSIS
To power up the chassis, refer to Figure 3-6 and proceed as follows:
1. Plug one end of the power cord (supplied with the power supply) into the ac power socket on the
front panel of the power supply. See Figure 3-6 for the power connections.
Figure 3-6 Connecting the Power Supply AC Power Cord
2. Plug the other end of the power cord into a dedicated 15A/120 Vac outlet for the 7C203-1.
3. If you are installing two power supplies, repeat steps 1 and 2, otherwise, proceed to step 4. For
power redundancy, plug the power cord from the second power supply into a separately fused
15A/120 Vac outlet.
4. Set the 0/| Power switch on the front panel of each power supply to |.
5. Ensure that the Power LED is green.
NOTE: If two power supplies are going to be installed, repeat the following procedure for each
power supply.
For proper redundancy using two 7C203-1 power supplies, the power cord from each power
supply must be connected to a dedicated 15-Ampere ac power circuit.
1 Power cord 2 Front panel ac power socket 3 Power outlet (120 Vac, 15A)
7C203-1
REDUNDANCY
PWR
100-125V~12.0A
200-240V~6.0A
50/60 Hz
0
7C203-1
REDUNDANCY
PWR
100-125V~12.0A
200-240V~6.0A
50/60 Hz
0
À
Á
Â