Enterasys Matrix 7H4382-49 Installation Guide Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
Using LANVIEW
DFE-Platinum Series Hardware Installation Guide 4-3
3. PresstheGROUPSELECTbuttonagainformorethanonesecond.Thisreturnsthe
7H438549tothedefaultstatusmodetomonitorRX(receive)andTX(transmit)
activity.
Table 41describestheLEDindicationsandprovidesrecommendedactionsas
appropriate.
Note: The terms used in Tab l e 4- 1 indicate the following:
Flashing indicates LED is flashing randomly.
Blinking indicates LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Alternating indicates LED is flashing in a steady rate other than 50% on, 50% off.
Table 4-1 LANVIEW LEDs
LED Color State Recommended Action
MGMT Off Off. This DFE module is NOT
the Management Module.
None.
Green Solid. This module is the
designated Management
Module.
None.
Amber Flashing. This is a
temporary indication that the
DFE module is saving data.
None.
CPU Off Power off. Ensure chassis has adequate power.
Amber Blinking. DFE module in
process of booting.
None.
Solid. Testing. If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green Blinking. Image starts
running.
None.
Solid. Functional. None.
Red Solid. Processor in reset. None.
Green and
Amber
Blinking. Indicates that the
DFE module is in the process
of shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE module.
Page view 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 91 92

Comments to this Manuals

No comments