show snmp notifyfilter
Enterasys D-Series CLI Reference 7-33
Example
ThisexampleshowshowtocleartheSNMPnotifyconfigurationfor“hello”:
D2(su)->clear snmp notify hello
show snmp notifyfilter
UsethiscommandtodisplaySNMPnotifyfilterinformation,identifyingwhichprofileswillnot
receiveSNMPnotifications.
Syntax
show snmp notifyfilter [profile] [subtree oid-or-mibobject] [volatile |
nonvolatile | read-only]
Parameters
Defaults
Ifnoparametersarespecified,allnotifyfilterinformationwillbedisplayed.
Mode
Switchcommand,readonly.
Usage
SeeAboutSNMPNotifyFiltersonpage 728formoreinformationaboutnotifyfilters.
Example
ThisexampleshowshowtodisplaySNMPnotifyfilterinformation.Inthiscase,thenotifyprofile
“pilot1”insubtree 1.3.6willnotreceiveSNMPnotificationmessages:
D2(su)->show snmp notifyfilter
--- SNMP notifyFilter information ---
Profile = pilot1
Subtree = 1.3.6
Filter type = included
Storage type = nonVolatile
Row status = active
profile (Optional)Displaysaspecificnotifyfilter.
subtreeoidor
mibobject
(Optional)Displaysanotifyfilterwithinaspecificsubtree.
volatile|
nonvolatile|read
only
(Optional)Displaysnotifyfilterentriesofaspecificstoragetype.