clear rmon alarm
15-12 RMON Configuration
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
AnRMONalarmentrycanbecreatedusingthiscommand,configuredusingthesetrmonalarm
propertiescommand(“setrmonalarmpropertiesonpage 1510),thenenabledusingthis
command.AnRMONalarmentrycanbecreatedandconfiguredatthesametimebyspecifying
anunusedindexwiththe
setrmonalarmpropertiescommand.
Example
ThisexampleshowshowtoenableRMONalarmentry3:
D2(rw)->set rmon alarm status 3 enable
clear rmon alarm
UsethiscommandtodeleteanRMONalarmentry.
Syntax
clear rmon alarm index
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoclearRMONalarm entry1:
D2(rw)->clear rmon alarm 1
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
enable Enablesthisalarmentry.
index Specifiestheindexnumberofentrytobecleared.