Enterasys D-Series Specifications Page 393

  • Download
  • Add to my manuals
  • Print
  • Page
    / 540
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 392
set mac agetime
Enterasys D-Series CLI Reference 14-21
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheMACtimeoutperiod:
D2(su)->show mac agetime
Aging time: 300 seconds
set mac agetime
UseThiscommandtosetthetimeoutperiodforaginglearnedMACentries.
Syntax
set mac agetime time
Parameters
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtosettheMACtimeoutperiod:
D2(su)->set mac agetime 250
clear mac agetime
UsethiscommandtoresetthetimeoutperiodforaginglearnedMACentriestothedefaultvalue
of300seconds.
Syntax
clear mac agetime
Parameters
None.
Defaults
None.
time SpecifiesthetimeoutperiodinsecondsforaginglearnedMAC
addresses.Validvaluesare10to1,000,000seconds.Defaultvalueis300
seconds.
Page view 392
1 2 ... 388 389 390 391 392 393 394 395 396 397 398 ... 539 540

Comments to this Manuals