Overview of DFE-Platinum Module Shutdown Procedure
4-6 Troubleshooting
Overview of DFE-Platinum Module Shutdown Procedure
TheDFEmodulesinstalledinaMatrix E7,Matrix N3,Matrix N5,orMatrix N7chassisare
interdependentandoperateunderasingleIPaddressasasingle,distributedswitchsystem
(hardware,databases,andpersistentstorage).Inthisoperatingenvironment,theDFEmodule
mustshutdowninanorderlyfashiontoensurethattheothermodulesin
thesystemandother
devicesonthenetworkarenotifiedoftheimpendingchange.Thedevicescanthenmake
intelligentdecisionsandstabilizethenetworkbeforethechangeismade;therebyincreasing
networkavailability.
YoucanshutdownaDFEmoduleinanoperatingsystemusingthe
OFFLINE/RESETswitchshown
inFigure 4 ‐2.TherearetwoprocedurestoshutdownaDFEmodule.
• “RecommendedShutdownProcedureUsingOFFLINE/RESETSwitch”(page 4‐7)
• “LastResortShutdownProcedureUsingOFFLINE/RESETSwitch”(page 4‐7)
Figure 4-2 OFFLINE/RESET Switch
Caution: Do not remove a DFE module from an operating chassis system before reading the
following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las siguientes
instrucciones y la información suministrada.
1 OFFLINE/RESET switch (in similar location on all DFE modules)
COM
OFFLINE/
RESET
GROUP 3
GROUP 1 GROUP 2
CPU
MGMT
1X
6X
7G4202-72
Gb ENET